Features |
The DU-3282 has a real-time open circuit monitoring function, which limits the instrument to only be tested when the circuit is normal. During the entire testing process, as long as there is a circuit disconnection, the test will be stopped immediately and an alarm will be triggered. The indicator light will indicate the faulty position, and the 100% accuracy test will be maintained. |
HI-port test |
AC: |
Test voltage: 100~5000V
Detecting current: 0.10mA ~ 15.00mA
Output frequency: 50/60HZ |
Voltage Accuracy: ±1% +5 digits
Cutoff Current:±1.5% +5 digits |
|
DC: |
Test voltage: 100~6000kV
Detecting current: 0.10mA ~ 7.500mA |
Voltage Accuracy: ±1% +5 digits
Cutoff Current: ±1.5% +5 digits
|
ARC tese |
ARC: |
AC
Detecting current: 0.50mA ~ 12.00mA |
DC:
Detecting current : 0.50mA ~ 5.00mA
|
IR test |
IR:
|
Test voltage: DC: 100 ~ 1000V
Test scope: 1 MΩ~ 9,999MΩ
|
Voltage Accuracy: ±1% +5 digits
¡Ù500V : 1¡ã1000MΩ ±5%
¡Ù500V : 1001¡ã9999MΩ ±15%
< 500V : 1¡ã 200MΩ ±10%
< 500V : 201¡ã9999MΩ ±15%
|
|
Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV
Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA
3 in 1 functions, with AC, DC Hi-Pot test, Insulation test.
8 independent real-time open check channels, check the connection of fixture and DUT or
wiring, ensure the DUT tested. From test button pressed till test finish, the open check
continued.
Large LCD display, easy to setup and read
Provided 50/60Hz test frequency selection
9 steps test setup for each memory set, 100 sets of memory, easy to save test setting data
Arcing detect function
8 ports scanning function and Independent 8 channels real-time open check
Real-time check function, to ensure your products tested, no more loss test. |
Specification |
Model |
DU-3328 |
Scan Test |
8 Ports ± phase |
Real tame Chack |
8 Ports Ch1~Ch8<4kΩ , 4 Ports C1~C4<300kΩ |
Output Voltage |
AC: 0~5000V / DC: 0~6000V |
Output Current |
0.5mA~15mA / DC: 0.5mA~7.5mA |
IR testt(Option) |
DC:100~1000V, 1~9999W |
Scan Test |
8 Ports ±phase |
Real time check |
12 Ports |
Output Voltage |
AC: 0 ~ 5,000V / DC: 0 ~ 6,000V. Digital setting (4 digits),
10V/ step, adjustable with < / > keys |
Voltage Regulation |
≦1%+5V |
Waveform&Frequency |
Sine Wave 50Hz/60Hz selectable |
Voltmeter Accuracy |
4 digits, ±1 % of reading +5 digits |
Output Current |
AC : 0.01mA ~ 15.00mA, DC: 0.01mA ~ 7.5mA |
Current Meter Accuracy |
4 digits, ±(1.5% of reading +5 digits) |
Arc Detection Functio |
0.5mA ~ 15mA(DC0.5mA ~ 7.5mA) 0.01mA/Steps. (0.0mA is OFF) |
Test Time |
0.5 ~ 999.9 s ( ±20 ms), 0.1s / Steps. (0.0 s is OFF) |
Ramp up Time |
0.1 ~ 999.9 s ( ±20 ms), 0.1s/Steps. (0.0 s is OFF) |
PASS/FAIL Judgement |
Windows comparator system
HI-limit: 0.10-15.00mA, Digital setting (4 digits), 0.01mA/Steps
LO-limit: 0.05-7.50mA, Digital setting (4 digits), 0.01mA/Steps
Arc Detection: 0.5mA-15mA (0.5-7.50mA), 0.01mA/Steps
(LO-limit & Arc Detection setting 0.0mA is OFF) |
Judgement Accuracy |
±(1% of setting + 50 mA) |
Insulation Resistance Test |
Measuring Voltage |
DC: 100 ~ 1,000V, Digital setting, 10V/steps. |
Voltmeter Accuracy |
4 digits, ±1 % of reading +5 digits |
Measuring Range |
1 ~ 9,999 MW |
Current Meter Accuracy |
4 digits, ±(1.5% of reading +5 digits) |
Measuring Accuracy |
≧500V:1-1000MW, ±5% of reading
≧500V:1001-9999MW, ±15% of reading
< 500V : 1 ~ 200MW, ±10% of reading
< 500V : 201 ~ 1,000MW, ± 15% of reading |
Judgement Waiting time |
0.1 ~ 999.9 s ( ± 20 mS), 0.1s / Steps |
PASS/FAIL Judgement |
Windows comparator system.
Both HI and LO limit values can be set with the measuring range.
Note: When the lower limit value is greater than 2000 MW, a judgement waiting time of 1.0 second or more is necessary |
Judgement Accuracy |
Same as measurina accuracy |
Test Time |
0.5 to 999.9 s ( ±20ms ), 0.1sec/Steps.(0.0 sec is OFF) |
Test Modes |
Auto Test |
Up to 9 test steps with different test parameters |
Single Test |
Execution withstanding voltage test or insulation resistance test. |
Auto Scanning Test |
Linked with Model DU330 Scan Box, it performs auto test for objects having two or more points. (Optional Scanner Interface and Box are required) |
Output Power Source Protection Function |
Fast Output Cut off |
< 0.4ms |
Panel Operation Lock |
YES |
Power On Data Rally |
YES |
Reset Protection Key |
YES |
Other Function |
Display |
240x64 Dot Graphic LCM, CFL back light display |
Signal Output |
PASS, FAIL, and TEST with relay contact signal |
Data Hold |
YES |
Judgement Result |
Display PASS/ FAIL and Alarm |
Memory Storage |
01 to 99, 99 sets of memory, each set of memory includes 9 steps |
Remote Control |
9 Pins D-type connector, TEST/RESET/RMT_ENABLE |
Interlock Function |
The test voltage cannot be generated unless the interlock input terminal is short-circuited |
Ambient Temperature and Relative Humidity |
Specifications range |
5 to 35°C(41 to 95 F), 20 to 80%RH |
Operable range |
0 to 40°C(32 to 104 F), 20 to 80%RH |
Storage range |
-20 to 70°C(4 to 158 F), ≦80%RH |
Power Requirement |
Line Voltage |
A: 90 ~ 110V B: 104 ~ 125V C: 194 ~ 236V D: 207 ~ 250V |
Frequency |
50 or 60 Hz |
Power Consumpt |
When no-load: < 70VA When with Rated Load: >300VA |
Insulation Resistance |
≧30MW, with 500V DC |
Withstanding Voltage |
1,000VAC, for 1 minute |
Dimension |
DU-3328 |
365(W) x 105(H) x 350(D) mm |
DU-330c |
365(W )x 110(H) x 350(D) mm |
Weight |
DU-3328: 11Kg DU-330C: 5Kg |
Accessories |
Operation Manual, Power cord, High test lead wire / 1 meter long, 2A Fuse/fast blow(in fuse holder), Certificate of calibration |